Metallic or absorbable implants for ankle fractures:A comparative study of infections in 3,111 cases

Authors

  • Ilkka Sinisaari
  • Hannu Pätiälä
  • Ole Böstman
  • E Antero Mäkelä
  • Eero Hirvensalo
  • Esa K Partio
  • Pertti Törmälä
  • Pentti Rokkanen

DOI:

https://doi.org/10.3109/17453679608995602

Abstract

Absorbable fracture fixation has been in clinical use since 1984. Our study compares the infection rates and some infection parameters between metallic (2073 patients) and absorbable fracture fixation devices (1012 patients) in displaced ankle fractures. The infection rate associated with metallic fixation was 4.1%, compared with 3.2% absorbable fixation (p 0.3). The patients who had a wound infection were older when metallic fixation was used (p 0.01). They also had a bi- or trimalleolar fracture more often than did patients treated with absorbable fracture fixation, but this difference did not have a significant effect on the wound infection rate (p 0.2). The infections were mostly caused by microorganisms of the Staphylococcus species. Deep infections were equally common with both fixation methods (0.4%), but there was some variation in the bacterial spectrum.

Downloads

Download data is not yet available.

Downloads

Published

1996-01-01

How to Cite

Sinisaari, I., Pätiälä, H., Böstman, O., Mäkelä, E. A., Hirvensalo, E., Partio, E. K., … Rokkanen, P. (1996). Metallic or absorbable implants for ankle fractures:A comparative study of infections in 3,111 cases. Acta Orthopaedica, 67(1), 16–18. https://doi.org/10.3109/17453679608995602