Osseointegrated silicone implants: 18 patients with 57 MCP joints followed for 2 years

Authors

  • Karin Möller
  • Christer Sollerman
  • Mats Geijer
  • Per-Lngvar Brånemark

DOI:

https://doi.org/10.3109/17453679909011245

Abstract

20 patients were operated on consecutively with osseointegrated MCP joint prostheses in 64 joints at our department between September 1993 and February 1995. The one-stage procedure included joint resection and cancellous bone grafting from the iliac crest before insertion of screw-shaped titanium fixtures, connected with a flexible silicone spacer. 18 patients (57 joints) were clinically and radiographically examined at median 28 (1 8-37) months postoperatively. Indications for surgery were joint destruction due to chronic arthritis in 17 patients (56 joints), and posttraumatic arthrosis in 1 patient (1 joint). Postoperative median range of motion was 40 (15-85) degrees, with an extension deficit of 30 (-20-70) degrees. 16 patients were satisfied, and had good pain relief and substantially improved postoperative hand function, evaluated with the standardized Sollerman hand function test. Radiographic osseointegration was obtained in 11 2 of 11 4 titanium fixtures (98%), but fracture of the silicone spacer was observed in 14 implants (25%). We conclude that osseointegration of longitudinal titanium fixtures in the bone marrow canal is possible in a one-stage procedure, but our findings show the need for a new, more durable joint spacer.

Downloads

Download data is not yet available.

Downloads

Published

1999-01-01

How to Cite

Möller, K., Sollerman, C., Geijer, M., & Brånemark, P.-L. (1999). Osseointegrated silicone implants: 18 patients with 57 MCP joints followed for 2 years. Acta Orthopaedica, 70(2), 109–115. https://doi.org/10.3109/17453679909011245