Is a hollow centralizer necessary when using a polished, tapered, cemented femoral stem?
DOI:
https://doi.org/10.1080/17453674.2017.1315553Abstract
Background and purpose — A tapered, polished and collarless stem is normally equipped with a hollow centralizer to prevent the stem from becoming end-bearing in the cement as the stem subsides. In a randomized clinical trial, we evaluated such a stem (MS-30), which was initially introduced with a solid centralizer but was later recommended to be fitted with a hollow centralizer. We hypothesized that while the stem would sink more, it would become rotationally stable and have less retroversion with a hollow centralizer than with a solid centralizer. Patients and methods — We randomized 60 patients with primary hip arthritis to receive either a hollow centralizer or a solid centralizer with the stem. The effect was evaluated over a 10-year follow-up period with repeated RSA examinations, conventional radiographs, and clinical follow-ups using the WOMAC and SF-12 questionnaires. Results — At 10-year follow-up, the group with hollow centralizers had subsided more than the group with solid centralizers (1.99 mm (hollow) as opposed to 0.57 mm (solid); p < 0.001). However, rotation was similar at 10-year follow-up (mean retroversion 1.34° (hollow) and 1.30° (solid)). Both groups showed excellent 10-year results, with similar clinical outcome, and none of the stems were radiographically loose or had been revised. Interpretation — As expected, there was more subsidence in the group with hollow centralizers, and with similar magnitude to that reported in earlier RSA studies on conceptually similar prostheses. Interestingly, there was no difference in the rotational behavior of the prostheses. This stem type appears to have a design that, regardless of the type of centralizer and the possibility of subsidence, withstands the rotational forces it is subjected to very well. This study does not support the need for a hollow centralizer for these types of stems.Downloads
Download data is not yet available.
Downloads
Additional Files
Published
2017-07-04
How to Cite
Weber, E., Olsson, C., Kesteris, U., & Flivik, G. (2017). Is a hollow centralizer necessary when using a polished, tapered, cemented femoral stem?. Acta Orthopaedica, 88(4), 377–382. https://doi.org/10.1080/17453674.2017.1315553
Issue
Section
Articles
License
Copyright (c) 2017 Erik Weber, Christer Olsson, Uldis Kesteris, Gunnar Flivik
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License.
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.