A comparative study of intraoperative frozen section and alpha defensin lateral flow test in the diagnosis of periprosthetic joint infection

Authors

  • Irene K Sigmund Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna
  • Johannes Holinka Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna
  • Susanna Lang Medical University of Vienna, Department of Pathology, Vienna, Austria
  • Sandra Stenicka Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna
  • Kevin Staats Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna
  • Gerhard Hobusch Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna
  • Bernd Kubista Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna
  • Reinhard Windhager Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna

DOI:

https://doi.org/10.1080/17453674.2019.1567153

Abstract

Background and purpose — For decision-making (aseptic vs. septic), surgeons rely on intraoperatively available tests when a periprosthetic joint infection (PJI) cannot be confirmed or excluded preoperatively. We compared and evaluated the intraoperative performances of the frozen section and the alpha defensin lateral flow test in the diagnosis of PJI.

Patients and methods — In this prospective study, consecutive patients with indicated revision surgery after arthroplasty were included. Patients were classified as having PJI using the MusculoSkeletal Infection criteria. The presence of alpha defensin was determined using the lateral flow test intraoperatively. During revision surgery, tissue samples were harvested for frozen and permanent section. Analysis of diagnostic accuracy was based on receiver-operating characteristics.

Results — 101 patients (53 hips, 48 knees) were eligible for inclusion. Postoperatively, 29/101 patients were diagnosed with PJI, of which 8/29 cases were definitely classified as septic preoperatively. Of the remainder 21 septic cases, the intraoperative alpha defensin test and frozen section were positive in 13 and 17 patients, respectively. Sensitivities of the alpha defensin test and frozen section were 69% and 86%, respectively. The area under the curves of both tests showed a statistically significant difference (p = 0.006).

Interpretation — The frozen section showed a significantly higher performance compared with the alpha defensin test and a near perfect concordance with the definitive histology, and therefore remains an appropriate intraoperative screening test in diagnosing PJI. Although the sensitivity of the alpha defensin test was lower compared with that of frozen section, this test is highly specific for confirming the diagnosis of PJI.

Downloads

Download data is not yet available.

Downloads

Published

2019-01-23

How to Cite

Sigmund, I. K., Holinka, J. ., Lang, S., Stenicka, S., Staats, K. ., Hobusch, G., … Windhager, R. (2019). A comparative study of intraoperative frozen section and alpha defensin lateral flow test in the diagnosis of periprosthetic joint infection. Acta Orthopaedica, 90(2), 105–110. https://doi.org/10.1080/17453674.2019.1567153

PlumX (by Elsevier) is an altmetrics platform that tracks and visualizes the online attention, usage, captures, citations, and social media engagement.