Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up
DOI:
https://doi.org/10.2340/17453674.2026.47063Keywords:
Bone, Fractures, Implants, Paediatric orthopaedics, RemovalAbstract
Background and purpose: Removal of flexible intramedullary nails (FIN) in children with femoral shaft fractures has been considered unnecessary when nails are left unbent flush to the bone. We aimed to evaluate the frequency and timing of nail removal on demand.
Methods: This is an observational follow-up study including consecutive 3–14-year-old children with femoral shaft fractures treated during 2011–2018 with FIN. The instruction was to leave the distal ends of the nails unbent above the distal femoral physis. Alignment of the fracture and position of the nails were assessed after nailing and during follow-up. Data on nail removal rates and timing was collected with at least 5 years of follow-up. The outcomes for children with correctly placed nails were compared with those with nails that were too long, defined as cut at or below the distal femoral physis evaluated from postoperative radiographs.
Results: 55 consecutive children were included. All fractures healed in satisfactory alignment. FINs were too long in 24 patients (20 distally, 4 proximally). Hardware was removed in 37 (67%) children at a median of 2.4 years from surgery because of pain (range 0.3–9.3). Removal occurred in 21/24 of those with too long nails, and in 16/31 patients with correctly applied FIN, RR 1.7 (95% confidence interval 1.2–2.5, P = 0.005).
Conclusion: Half of the children with unbent FIN placed flush to the bone in femoral shaft fractures had removal of nails. Extending the nail to or below the distal femoral growth plate leads to hardware removal in nearly all cases, mainly due to pain.
Downloads
References
Irani R N, Nicholson J T, Chung S M. Long-term results in the treatment of femoral-shaft fractures in young children by immediate spica immobilization. J Bone Joint Surg Am 1976; 58(7): 945-51. PMID: 977626.
Henderson O L, Morrissy R T, Gerdes M H, McCarthy R E. Early casting of femoral shaft fractures in children. J Pediatr Orthop 1984; 4(1): 16-21. doi: 10.1097/01241398-198401000-00004.
Ferguson J, Nicol R O. Early spica treatment of pediatric femoral shaft fractures. J Pediatr Orthop 2000; 20(2): 189-92. PMID: 10739280.
Palmu S A, Lohman M, Paukku R T, Peltonen J I, Nietosvaara Y. Childhood femoral fracture can lead to premature knee-joint arthritis. 21-year follow-up results: a retrospective study. Acta Orthop 2013; 84(1): 71-5. doi: 10.3109/17453674.2013.765621.
Flynn J M, Luedtke L M, Ganley T J, Dawson J, Davidson R S, Dormans J P, et al. Comparison of titanium elastic nails with traction and a spica cast to treat femoral fractures in children. J Bone Joint Surg Am 2004; 86(4): 770-7. doi: 10.2106/00004623-200404000-00015.
Narayanan U G, Hyman J E, Wainwright A M, Rang M, Alman B A. Complications of elastic stable intramedullary nail fixation of pediatric femoral fractures, and how to avoid them. J Pediatr Orthop 2004; 24(4): 363-9. doi: 10.1097/00004694-200407000-00004.
Brattgjerd J E, Aasheim C, Rosenberg A, Fotland C, Halvorsen V. Long-term implant retention after impacted elastic stable intramedullary nailing in pediatric diaphyseal forearm fractures: a retrospective cohort study. Acta Orthop 2026; 97: 225-31. doi: 10.2340/17453674.2026.45693.
Ligier J N, Metaizeau J P, Prevot J, Lascombes P. Elastic stable intramedullary nailing of femoral shaft fractures in children. J Bone Joint Surg Br 1988; 70(1): 74-7. doi: 10.1302/0301-620X.70B1.3339064.
Raney E M, Freccero D M, Dolan L A, Lighter D E, Fillman R R, Chambers H G. Evidence-based analysis of removal of orthopaedic implants in the pediatric population. J Pediatr Orthop 2008; 28(7): 701-4. doi: 10.1097/BPO.0b013e3181875b60.
Lohiya R, Bachhal V, Khan U, Kumar D, Vijayvargiya V, Sankhala S S, et al. Flexible intramedullary nailing in paediatric femoral fractures: a report of 73 cases. J Orthop Surg Res 2011; 6(64): 1-10. doi: 10.1186/1749-799X-6-64.
Morshed S, Humphrey M, Corrales L A, Millett M, Hoffinger S A. Retention of flexible intramedullary nails following treatment of pediatric femur fractures. Arch Orthop Trauma Surg 2007; 127: 509-14. doi: 10.1007/s00402-007-0286-y.
Luhmann S J, Schootman M, Schoenecker P L, Dobbs M B, Gordon J E. Complications of titanium elastic nails for pediatric femoral shaft fractures. J Pediatr Orthop 2003; 23(4): 443-7. PMID: 12826940.
Singh A, Bierrum W, Wormald J, Ramachandran M, Firth G, Eastwood D. Plate fixation versus flexible intramedullary nails for management of closed femoral shaft fractures in the pediatric population: a systematic review and meta-analysis of the adverse outcomes. J Child Orthop 2023; 17(5): 442-52. doi: 10.1177/18632521231190713.
Additional Files
Published
How to Cite
License
Copyright (c) 2026 Nicolas Robert Nietosvaara, Jussi Kosola, Yrjänä Nietosvaara, Jani Puhakka, Ilkka Helenius, Topi Laaksonen

This work is licensed under a Creative Commons Attribution 4.0 International License.
PlumX (by Elsevier) is an altmetrics platform that tracks and visualizes the online attention, usage, captures, citations, and social media engagement.