Amputation and prosthetic fitting in a patient with guépar endoprosthesis
DOI:
https://doi.org/10.3109/17453677708985119Abstract
Ischaemic gangrene of the foot in a patient previously fitted with an arthroplasty of the knee (Guépar) was treated with below-knee amputation. The endoprosthesis was retained and the patient was fitted with a modified PTB prosthesis. The functional result is satisfactory.Downloads
Download data is not yet available.
Downloads
Published
1977-01-01
How to Cite
Paradystal, T. (1977). Amputation and prosthetic fitting in a patient with guépar endoprosthesis. Acta Orthopaedica, 48(1), 105–107. https://doi.org/10.3109/17453677708985119
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.