Instability of trochanteric hip fractures following internal fixation: A radiographic comparison of the Richards sliding screw-plate and the McLaughlin nail-plate
DOI:
https://doi.org/10.3109/17453678408992950Abstract
A comparison was made of the McLaughlin nail plate and the Richards sliding screw-plate techniques for fixation of trochanteric hip fractures. The series included 96 patients in each group. The fractures were followed radiographically for 3 months. Technical failures were encountered in 31 per cent of the McLaughlin fractures and in 8 per cent of the Richards fractures; reoperation was performed in 9 per cent in McLaughlin vs none in the Richards fractures. The main failure was varus displacement in both groups, always combined with lateral cutting of the screw in the Richards fractures, and often combined with failure of the nail-plate junction in McLaughlin fractures. Our study has shown that the sliding screw-plate is superior to the nail plate in both stable and unstable fractures.Downloads
Download data is not yet available.
Downloads
Published
1984-01-01
How to Cite
Moller, B. N., Lucht, U., Grymer, F., & Bartholdy, N. J. (1984). Instability of trochanteric hip fractures following internal fixation: A radiographic comparison of the Richards sliding screw-plate and the McLaughlin nail-plate. Acta Orthopaedica, 55(5), 517–520. https://doi.org/10.3109/17453678408992950
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.