https://doi.org/10.3109/17453678408992329Abstract
Prosthetic positioning and overall postoperative alignment were studied in 138 consecutive total knee replacements, using the Insall/Burstein® total condylar knee system. Overall alignment was within 7 ± 5 degrees of valgus in 63 per cent of the knees, while tibial component positioning was within 4 degrees of tilt in any direction in 53 per cent of the knees. A radiolucency index incorporating width and extent of radiolucent zones at the tibia was shown to progress from 3 months to 2 years postoperatively. The radiolucency index 2 years postoperatively was higher with postoperative varus alignment in the rheumatoid arthritis group; a tibial component tilt of more than 4 degrees in any direction increased the radiolucency index in both treatment groups.Downloads
Download data is not yet available.
Downloads
Published
1984-01-01
How to Cite
Hvid, I., & Nielsen, S. (1984). Total condylar knee arthroplasty: Prosthetic component positioning and radiolucent lines. Acta Orthopaedica, 55(2), 160–165. https://doi.org/10.3109/17453678408992329
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.