Bone atrophy after plate fixation: Computed tomography of femoral shaft fractures
DOI:
https://doi.org/10.3109/17453678508994361Abstract
Twelve patients with previous femoral shaft fracture treated by rigid plate fixation were examined by computed tomography (CT) scanning 1 or 2 days after plate removal. In the previously plated segment an average reduction in cortical density of 11 per cent was found, and the reduction was most pronounced in the cortex directly beneath the plate. No reduction in cortical thickness of the plated bone occurred. Proximal and distal to the site of the plate, and in the ipsilateral tibial shaft, a slight reduction in cortical density and thickness averaging 2–3 per cent was found.Downloads
Download data is not yet available.
Downloads
Published
1985-01-01
How to Cite
Terjesen, T., Nordby, A., & Arnulf, V. (1985). Bone atrophy after plate fixation: Computed tomography of femoral shaft fractures. Acta Orthopaedica, 56(5), 416–418. https://doi.org/10.3109/17453678508994361
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.