Fixation of osteochondral fractures: Fibrin sealant tested in dogs

Authors

  • Johnny Keller
  • Troels T. Andreessen
  • Frederic Joyce
  • Vibeke E. Knudsen
  • Peter H. JøSrgensen
  • Ulf Lucht

DOI:

https://doi.org/10.3109/17453678508993025

Abstract

Standardized osteochondral fractures in the left femoral condyle in 19 adult mongrel dogs were fixed with either fibrin sealant or Kirschner wire. Adaptation and mechanical strength after 4, 7 or 8, and 14 days were compared with an in vitro study of the initial strength of the fibrin sealant in osteochondral fractures. After 4 days, the maximum tensile strength was increased in the fibrin sealed group, whereas no difference in energy absorption at failure was found. Although the initial strength of the fibrin bond was low, the tendency to displacement was less in this group. Our results suggest that fibrin sealant can be used for fixation of small osteochondral fragments, provided that immobilisation is sufficient.

Downloads

Download data is not yet available.

Downloads

Published

1985-01-01

How to Cite

Keller, J., Andreessen, T. T., Joyce, F., Knudsen, V. E., JøSrgensen, P. H., & Lucht, U. (1985). Fixation of osteochondral fractures: Fibrin sealant tested in dogs. Acta Orthopaedica, 56(4), 323–326. https://doi.org/10.3109/17453678508993025