Refracture of the hip rare after removal of fixation device
DOI:
https://doi.org/10.3109/17453678609014765Abstract
We studied 99 patients who had had the fixation device removed from a healed hip fracture. During a total of 630 patient years 17 second hip fractures were observed, but only two of these were in the previously fractured hip. We conclude that the fixation device may be safely removed from a healed hip fracture.Downloads
Download data is not yet available.
Downloads
Published
1986-01-01
How to Cite
Finsen, V., & Benum, P. (1986). Refracture of the hip rare after removal of fixation device. Acta Orthopaedica, 57(5), 434–435. https://doi.org/10.3109/17453678609014765
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.