Complications at extraction of the ASIF epiphysiodesis screws
DOI:
https://doi.org/10.3109/17453678709146383Abstract
A retrospective study was performed of 30 consecutive patients operated on. with ASIF epiphysiodesis for slipped capital femoral epiphysis. During extraction, complications were encountered in 13/23 patients. A total of 38 screws were removed. Thirteen screws broke and another three screws were embedded in bone, making extensive chiseling of cortical bone necessary before extraction was possible. Due to the frequent complications at extraction, the ASIF epiphysiodesis screw is not suitable for treatment of the slipped capital femoral epiphysis.Downloads
Download data is not yet available.
Downloads
Published
1987-01-01
How to Cite
Larsson, S., & Friberg, S. (1987). Complications at extraction of the ASIF epiphysiodesis screws. Acta Orthopaedica, 58(5), 483–484. https://doi.org/10.3109/17453678709146383
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.