Stress shielding by rigid fixation studied in osteotomized rabbit tibiae
DOI:
https://doi.org/10.3109/17453678909149613Abstract
In 48 rabbits the bone-formation rates and strength in the tibial shaft, osteotomized and treated with rigid internal plate fixation, were compared with contralateral bones, which were treated with plate fixation without osteotomy. The plate fixation alone induced a 35 percent decrease in torsional strength after 12 weeks. The healing of the osteotomy counteracted the decrease in strength induced by stress protection of the rigid plate at 6 weeks, but this effect subsided within 12 weeks. The osteotomy also induced a 2-3-fold increase in the synthesis of bone matrix and mineral accretion of the bone underlying the plate at 6 and 9 weeks when compared with the contralateral side, which was plated but not osteotomized. The bone-formation levels returned to normal within 12 weeks; and the bone underlying the plate became subject to atrophy, resulting in decreased mechanical strength.Downloads
Download data is not yet available.
Downloads
Published
1989-01-01
How to Cite
Låtman, P., Nilsson, O. S., Brosjö, O., & Strömberg, L. (1989). Stress shielding by rigid fixation studied in osteotomized rabbit tibiae. Acta Orthopaedica, 60(6), 718–722. https://doi.org/10.3109/17453678909149613
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.
PlumX (by Elsevier) is an altmetrics platform that tracks and visualizes the online attention, usage, captures, citations, and social media engagement.