Limb lengthening by physeal distraction
DOI:
https://doi.org/10.3109/17453678909149241Abstract
I evaluated 10 consecutive lengthenings through the upper tibial physis in 9 patients. A bilateral frame consisting of two small-sized Wagner devices and two pairs of 4-mm transfixing pins with 5-mm-diameter central threads were used. The median lengthening was 6.7 cm. Complications were frequent. The risk of a growth disturbance is very high, and physeal distraction should therefore only be applied towards the end of the growth period.Downloads
Download data is not yet available.
Downloads
Published
1989-01-01
How to Cite
Bjerkreim, I. (1989). Limb lengthening by physeal distraction. Acta Orthopaedica, 60(2), 140–142. https://doi.org/10.3109/17453678909149241
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.