Improved positioning of the femoral stem with a centralizing device
DOI:
https://doi.org/10.3109/17453679008993507Abstract
Two series of patients operated on with total hip replacements for arthrosis are reported. The same prosthesis and operative and cementing techniques were used in both series, except that in Series 2 a centralizing device consisting of four triangular fins passed over the tip was also used to improve the positioning of the femoral stem. It was found that the position of the tip was more central in Series 2. No drawbacks were associated with the use of the device. We concluded that the centralizing device facilitated the positioning of the femoral stem tip.Downloads
Download data is not yet available.
Downloads
Published
1990-01-01
How to Cite
Egund, N., Lidgren, L., & Önnerfält, R. (1990). Improved positioning of the femoral stem with a centralizing device. Acta Orthopaedica, 61(3), 236–239. https://doi.org/10.3109/17453679008993507
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.