Biodegradable fixation of ankle fractures
DOI:
https://doi.org/10.3109/17453679209154762Abstract
In a prospective study, 25 displaced ankle fractures were treated with one or two biodegradable rods (Biofix), sizes 3.2 or 4.5 mm. In 2 cases the medial malleolus fractured during drilling. At the 1-year follow-up of 22 cases, the following complications had occurred: sinus formation in 1 case and osteolysis corresponding to the fracture line and/or drill channels in 9 cases, 2 of whom had symptoms. 2 patients had been reoperated on, one for pseudarthrosis and another for secondary fracture displacement. Because of the high complication rate and the unknown importance of osteolysis formation, we cannot recommend biodegradable fixation with rods of 3.2 or 4.5 mm length as a supplement to the treatment of displaced ankle fractures, particularly of medial fractures.Downloads
Download data is not yet available.
Downloads
Published
1992-01-01
How to Cite
Frøkjær, J., & Møller, B. N. (1992). Biodegradable fixation of ankle fractures. Acta Orthopaedica, 63(4), 434–436. https://doi.org/10.3109/17453679209154762
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.