101 hips were revised with cemented Lubinus prostheses after failed primary cemented arthroplasty, and followed for 5 (4–9) years. Radiographically, 41 hips (36 femoral stems and 13 acetabular components) had become loose. The use of an intramedullary plug at the revision did not prevent sinking of the prosthesis. No difference was found between conventional or pressure-injection cementation techniques. In cases where the stem was inserted in varus or the acetabular component was in malposition there was increased loosening. Patients below 50 years of age had oftener more than 5 mm sinking of the stem and more prosthesis loosenings.Downloads
Download data is not yet available.
Downloads
Published
1993-01-01
How to Cite
Wirta, J., Eskola, A., Hoikka, V., Honkanen, V., Lindholm, S., & Santavirta, S. (1993). Revision of cemented hip arthroplasties: 101 hips followed for 5 (4–9) years. Acta Orthopaedica, 64(3), 263–267. https://doi.org/10.3109/17453679308993621
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.