Radiographic loosening of cementless threaded acetabular cups No additional diagnostic value of arthrography in 30 patients
DOI:
https://doi.org/10.3109/17453679508995577Abstract
We compared arthrography with plain radiographs in 30 consecutive patients having a clinical diagnosis of loosening of a smooth-threaded acetabular prosthesis (Mecron, Berlin). Leakage of contrast at the interface between the ring and the bone on the medial side of the prosthesis was seen in 21 patients. Loosening of the cup was also visible on the plane radiographs and loosening was confirmed in all these patients at revision surgery. No false positive arthrographies were seen. In one patient, the arthrography was false negative because of a technical failure. We conclude that no additional information was obtained by arthrography.Downloads
Download data is not yet available.
Downloads
Published
1995-01-01
How to Cite
Seelen, J. L., Bruijn, J. D., Kingma, L. M., Bernoski, F. P., & Bloem, J. L. (1995). Radiographic loosening of cementless threaded acetabular cups No additional diagnostic value of arthrography in 30 patients. Acta Orthopaedica, 66(5), 415–417. https://doi.org/10.3109/17453679508995577
Issue
Section
Articles
License
Acta Orthopaedica (Scandinavica) content is available freely online as from volume 1, 1930. The journal owner owns the copyright for all material published until volume 80, 2009. As of June 2009, the journal has however been published fully Open Access, meaning the authors retain copyright to their work. As of June 2009, articles have been published under CC-BY-NC or CC-BY licenses, unless otherwise specified.