Elevated cobalt levels in metal-on-polyethylene knee megaprostheses: a prospective 1-year cohort study of 56 patients with hip and knee megaprostheses

Authors

  • Sarah Stammose Freund Department of Orthopedic Oncology, Aarhus University Hospital, Denmark https://orcid.org/0000-0002-9471-296X
  • Andrea Pohly Jeppesen Thorn Musculoskeletal Tumor Section of the Department of Orthopedic Surgery, Rigshospitalet – University of Copenhagen, Denmark
  • Ajay Puri Orthopedic Oncology, Tata Memorial Centre, HBNI, Mumbai, India
  • Michael Mørk Petersen Musculoskeletal Tumor Section of the Department of Orthopedic Surgery, Rigshospitalet – University of Copenhagen, Denmark https://orcid.org/0000-0002-2324-6420
  • Thomas Baad-Hansen Department of Orthopedic Oncology, Aarhus University Hospital, Denmark

DOI:

https://doi.org/10.2340/17453674.2024.40502

Keywords:

Chromium, Cobalt, Megaprosthesis

Abstract

Background and purpose: Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal-on-metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal-on-polyethylene knee and hip megaprostheses and their associations with other factors.
Methods: 56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry.
Results: A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0–3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0–0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections.
Conclusion: We found elevated serum ion levels in metal-on-polyethylene knee megaprostheses in contrast to metal-on-polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.

Downloads

Download data is not yet available.

References

Cohen D. How safe are metal-on-metal hip implants? BMJ 2012; 344(1): e1410-e. doi: 10.1136/bmj.e1410. DOI: https://doi.org/10.1136/bmj.e1410

Pahuta M, Smolders J M, Van Susante J L, Peck J, Kim P R, Beaule P E. Blood metal ion levels are not a useful test for adverse reactions to metal debris. Bone J Res 2016; 5(9): 379-86. doi: 10.1302/2046-3758.59.bjr-2016-0027.r1. DOI: https://doi.org/10.1302/2046-3758.59.BJR-2016-0027.R1

Langton D J, Joyce T J, Jameson S S, Lord J, Van Orsouw M, Holland J P, et al. Adverse reaction to metal debris following hip resurfacing. J Bone Joint Surg Br 2011; 93-B(2): 164-71. doi: 10.1302/0301-620x.93b2.25099. DOI: https://doi.org/10.1302/0301-620X.93B2.25099

Medicines and Healthcare Products Regulatory Agency. All metal-on-metal (MoM) hip replacements: updated advice for follow-up of patients; 2017 [cited 2023 September 26]. Available from: https://www.gov.uk/drug-device-alerts/all-metal-on-metal-mom-hip-replacements-updated-advice-for-follow-up-of-patients#fn:1.

Consensus statement: “Current Evidence on the Management of Metal-on-Metal Bearings. European Federation of National Associations of Orthopaedics and Traumatology (EFORT), European Hip Society (EHS), the German Arbeitsgemeinschaft Endoprothetik (AE) and the Deutsche Arthrosehilfe (DAH); 2012 [cited 2023 September 26]. Available from: https://www.efort.org/wp-content/uploads/2013/10/2012_05_10_MoM_Consensus_statement1.pdf.

Rieker C B, Wahl P. What the surgeon can do to reduce the risk of trunnionosis in hip arthroplasty: recommendations from the literature. Materials (Basel) 2020; 13(8). doi: 10.3390/ma13081950. DOI: https://doi.org/10.3390/ma13081950

Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case C P. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty 2004;19(8 Suppl 3): 78-83. doi: 10.1016/j.arth.2004.09.010. DOI: https://doi.org/10.1016/j.arth.2004.09.010

Daniel J, Ziaee H, Pradhan C, Pynsent P B, McMinn D J W. Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty. J Bone Joint Surg Br 2007;89-B(2): 169-73. doi: 10.1302/0301-620x.89b2.18519. DOI: https://doi.org/10.1302/0301-620X.89B2.18519

Case C P, Langkamer V G, Howell R T, Webb J, Standen G, Palmer M, et al. Preliminary observations on possible premalignant changes in bone marrow adjacent to worn total hip arthroplasty implants. Clin Orthop Relat Res 1996; (329 Suppl): S269-79. doi: 10.1097/00003086-199608001-00024. DOI: https://doi.org/10.1097/00003086-199608001-00024

Tower S S. Cobalt toxicity in two hip replacement patients. State of Alaska Epidemiology Bulletin 2010 (No. 14, May 28).

Fox K A, Phillips T M, Yanta J H, Abesamis M G. Fatal cobalt toxicity after total hip arthroplasty revision for fractured ceramic components. Clin Toxicol (Phila). 2016; 54(9): 874-7. doi: 10.1080/15563650.2016.1214274. DOI: https://doi.org/10.1080/15563650.2016.1214274

Paustenbach D J, Galbraith D A, Finley B L. Interpreting cobalt blood concentrations in hip implant patients. Clin Toxicol (Phila) 2014; 52(2): 98-112. doi: 10.3109/15563650.2013.857024. DOI: https://doi.org/10.3109/15563650.2013.857024

Laitinen M, Nieminen J, Reito A, Pakarinen T K, Suomalainen P, Pamilo K, et al. High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements. Acta Orthop 2017; 88(3): 269-74. doi: 10.1080/17453674.2017.1283846. DOI: https://doi.org/10.1080/17453674.2017.1283846

Friesenbichler J, Maurer-Ertl W, Sadoghi P, Lovse T, Windhager R, Leithner A. Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis. Int Orthop 2012; 36(3): 539-44. doi: 10.1007/s00264-011-1317-4. DOI: https://doi.org/10.1007/s00264-011-1317-4

Manninen E, Lainiala O, Karsikas M, Reito A, Jämsä P, Eskelinen A. Do cobalt or chromium accumulate in metal-on-metal hip arthroplasty patients who have mild, moderate, or severe renal insufficiency? Bone Joint J 2021; 103-b(7): 1231-7. doi: 10.1302/0301-620x.103b7.Bjj-2020-0836.R2. DOI: https://doi.org/10.1302/0301-620X.103B7.BJJ-2020-0836.R2

Christensen R, Ranstam J, Overgaard S, Wagner P. Guidelines for a structured manuscript: statistical methods and reporting in biomedical research journals. Acta Orthop 2023; 94: 243-9. doi: 10.2340/17453674.2023.11656. DOI: https://doi.org/10.2340/17453674.2023.11656

Jakobsen S S, Danscher G, Stoltenberg M, Larsen A, Bruun J M, Mygind T, et al. Cobalt-chromium-molybdenum alloy causes metal accumulation and metallothionein up-regulation in rat liver and kidney. Basic Clin Pharmacol Toxicol 2007; 101(6): 441-6. doi: 10.1111/j.1742-7843.2007.00137.x. DOI: https://doi.org/10.1111/j.1742-7843.2007.00137.x

Friesenbichler J, Sadoghi P, Maurer-Ertl W, Szkandera J, Glehr M, Ogris K, et al. Serum metal ion concentrations in paediatric patients following total knee arthroplasty using megaprostheses. BioMed Res Int 2014; 2014: 1-7. doi: 10.1155/2014/817257. DOI: https://doi.org/10.1155/2014/817257

Daniel J, Ziaee H, Pynsent P B, McMinn D J. The validity of serum levels as a surrogate measure of systemic exposure to metal ions in hip replacement. J Bone Joint Surg Br 2007; 89(6): 736-41. doi: 10.1302/0301-620x.89b6.18141. DOI: https://doi.org/10.1302/0301-620X.89B6.18141

Malek I A, Rogers J, King A C, Clutton J, Winson D, John A. The interchangeability of plasma and whole blood metal ion measurement in the monitoring of metal on metal hips. Arthritis 2015; 2015: 216785. doi: 10.1155/2015/216785. DOI: https://doi.org/10.1155/2015/216785

Houdek M T, Couch C G, Wyles C C, Taunton M J, Rose P S, Kremers H M, et al. Whole blood metal levels in the setting of an oncologic endoprosthesis: is there cause for concern? Clin Orthop Relat Res 2024; 482(2): 352-8. doi: 10.1097/corr.0000000000002805. DOI: https://doi.org/10.1097/CORR.0000000000002805

Scientific Committee on Emerging and Newly Identified Health Risks. The safety of metal-on-metal joint replacements with a particular focus on hip implants; 2014 [cited 2023 September 26]. Available from: https://ec.europa.eu/health/scientific_committees/emerging/docs/scenihr_o_042.pdf.

United States Food and Drug Administration. Information about soft tissue imaging and metal ion testing; 2019 [cited 2023 September 26]. Available from: https://www.fda.gov/medical-devices/metal-metal-hip-implants/information-about-soft-tissue-imaging-and-metal-ion-testing.

Hur C I, Yoon T R, Cho S G, Song E K, Seon J K. Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res 2008; 466(3): 696-9. doi: 10.1007/s11999-007-0093-3. DOI: https://doi.org/10.1007/s11999-007-0093-3

Hjorth M H, Mechlenburg I, Soballe K, Roemer L, Stilling M. The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations. J Orthop Translat 2019; 18: 74-83. doi: 10.1016/j.jot.2018.11.001. DOI: https://doi.org/10.1016/j.jot.2018.11.001

Khan M, Takahashi T, Kuiper J H, Sieniawska C E, Takagi K, Richardson J B. Current in vivo wear of metal-on-metal bearings assessed by exercise-related rise in plasma cobalt level. J Orthop Res 2006; 24(11): 2029-35. doi: 10.1002/jor.20206. DOI: https://doi.org/10.1002/jor.20206

Antoniou J, Zukor D J, Mwale F, Minarik W, Petit A, Huk O L. Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. J Bone Joint Surg Am 2008; 90(Suppl 3): 142-8. doi: 10.2106/jbjs.H.00442. DOI: https://doi.org/10.2106/JBJS.H.00442

Daniel J, Ziaee H, Pradhan C, McMinn D J. Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. J Bone Joint Surg Br 2009; 91(2): 176-9. doi: 10.1302/0301-620x.91b2.21654. DOI: https://doi.org/10.1302/0301-620X.91B2.21654

de Smidt K Q, Spierenburg G, Evenhuis R E, Bosma S E, van der Wal R J P, Broekhuis D, et al. Systemic metal ion concentrations in patients with hip and knee megaprostheses: a prospective cohort study. Arthroplast Today 2022; 18: 191-201.e1. doi: 10.1016/j.artd.2022.08.006. DOI: https://doi.org/10.1016/j.artd.2022.08.006

Published

2024-04-17

How to Cite

Freund, S. S., Thorn, A. P. J., Puri, A., Petersen, M. M., & Baad-Hansen, T. (2024). Elevated cobalt levels in metal-on-polyethylene knee megaprostheses: a prospective 1-year cohort study of 56 patients with hip and knee megaprostheses. Acta Orthopaedica, 95, 174–179. https://doi.org/10.2340/17453674.2024.40502

Issue

Section

Articles

Categories